Model: MPY600 Catalog: pressure controller Input signal: MV,DC,DA,R, J, K... Output signal: 0-10vdc, 0-5vdc, 4-20mA Application: pressure controller, temperature controller, pressure indicator, force indicator MPY600 apply to pressure controller, temperature controller, pressure indicator, force indicator. support to MV,DC,DA,R, J, K signal input and 0-10vdc, 0-5vdc, 4-20mA, RS232/485 signal output. |
REF PIC |
(1) | Display | Dual 4-digit Green and Red LEDs |
(2) | Resolution | 0.2% FSO ± 1 |
(3) | LEDs | Out, Alarm-1, Alarm-2, Calibration |
(4) | Input Sensibility | 2.5mv/V or 3.3 mV/V (automatic selection) |
(5) | Sampling Speed | 20 per second |
(6) | Excitation Voltage | +9 VDC (output to transducer) |
(7) | Temperature Input | Thermocouple “E”, “J”, “K” |
(8) | All Output Relays | Relay 220V 1A |
(9) | Retransmission | 4~~20 mA standard current loop |
(10) | Communication | RS-485 MODBUS( MPY602 Only) |
(11) | Alarm Range | 0001 – 9999 PSI or Bar (configurable) |
(12) | Temperature | 0 - 55°C |
(13) | Humidity | <= 80% RH |
(14) | Calibration | 80% FSO (Full Scale Output) |
(15) | Power Supply | 110/220VAC or +24VDC (designated while purchasing) |
(16) | Size | MPY602H: 96mm×46mm×100 mm (W x H x D) MPY602: 96mm x 96mm x 110 mm (W x H x D) |
(17) | Panel Cutout | MPY602H: 96mm x 46mm (W x H) MPY602: 96mm x 96mm (W x H) |
(18) | Weight | 400(Maximum) grams |
|
MODEL FUNCTION OPTION |
Contents | Explanation |
MPY500 | Pressure controller |
MPY600 | Pressure and temperature controller |
MPY900 | Pressure controller with PID |
Size | A- | NA |
B- | 96×96×112(W×H×L) |
C- | oblong96×48×112(W×H×L) |
D- | 72(W)×72(H)×112(L) |
E- | 48(W)×48(H)×112(L) |
Panel( Annotation 1) | H | oblong Display Digital Display(green) |
S | Upright, Display Digital Display(green) |
G | upright double digital + double light beams (only for 2-channel meter, 1 channel green, 2 channels red) |
Channels | 1 | 1-channel meter |
2 | 2-channel meter |
3 | NA |
4 | NA |
Input Signals | E | Thermocouple, Radiation Thermometer |
R | Thermoresistance, resistance |
I | DC |
V | DV |
M | mV DC mV |
W | potentiometer |
L | Long-Distance Pressure Gauge |
Number of Alarm points | T | T0: no alarm T1~T8: 1-8 points alarm |
Transforming Output | A0 | no Output |
A1 | Current Output(4~20)mA |
A2 | Voltage Output(0~5)V、(1~5)V |
A3 | Voltage Output(0~10)V |
A4 | other Output |
A5 | double outputs |
External Power Supply | B0 | no external power supply |
B1 | External Power Supply of 24V DC |
B2 | External Power Supply of 12V DC |
B3 | external power of precise voltage |
B4 | external power of precise constant current |
B5 | others |
Communication Interface | S0 | Communication Interface |
S1 | RS-232 Interface |
S2 | RS-485 Interface |
S3 | RS-422 Interface |
S4 | BCD Interface(only for A and B) |
Work voltage | V0 | 220V AC |
V1 | 24V DC |
V2 | 12V DC |
V3 | others |
Printing | P | Printing supported, non essential |
Memory Unit | R | N |
Nonstandard Function | NA | |