Product Description 0.05 -level measurement accuracy, 10 times per second measurement and control speed Zero, peak, valley processing Upper limit, lower limit, deviation and other alarm methods 1 point switch input Basic Specifications Basic Specifications voltage | AC power | 100-240V AC 50/60Hz | AC/DC power supply | 10-24V AC 50/60Hz; 10-24V DC | Power consumption | AC power | Below 7VA | AC/DC power supply | AC: below 6 VA; DC: below 5W | Allowable voltage range | 90 ~ 110 % of supply voltage | Insulation resistance | 100MΩ or more (500 V DC MEGA reference) | withstand voltage | 1 minute at 2000 V AC 50/60Hz | Anti-jamming | IEC6 1000-4-2(electrostatic discharge), level Ⅲ; IEC6 1000-4-4(electrical fast transient burst), level Ⅲ; IEC6 1000-4-5(surge), level Ⅲ | degree of protection | IP65 (front part of the product) | surroundings | temperature | -10 ~55°C; storage -25 ~ 65°C | humidity | 35 ~ 85 %RH; storage 35 ~ 85 %RH |
Input specifications Measure control speed | 10 times/second or more | basic error | ±0.05 %FS | display range | -19999~45000 | input signal | Voltage | V | 0-5V DC; 1-5V DC | electric current | I | 4-20/0-10/0-20 mA | mV | m | ±20, ±50, ±90mV | digital filtering | Inertia; average value; moving average, etc. |
3 Specifications of optional accessories Contact output | T1-T4 | 1-4 points, 250VAC/3A resistive load | contact input | K | 1 point external binary input, used for clearing | Analog output (resolution 1/3000) | A1 | Current output (4-20) mA, (0-10) mA, (0-20) mA | A2 | Voltage output (1-5) V, (0-5) V | Communication Interface | S1 | TC ASCII protocol RS232 | Speed: 2400; 4800; 9600; 19200 Address : 0-99 Response time: 500μS (measured value) | S2 | TC ASCII protocol RS485 | M1 | Modbus-RTU protocol RS232 | M2 | Modbus-RTU protocol RS485 | External power supply | B1 | 24V±5%, below 50mA | B1G | 24V±5%, below 100mA | B2 | 12V±5%, below 50mA | B2G | 12V±5%, below 100mA | B3 | Precision power supply, generally 10V±2%, 30ppm, below 100mA |
Code description content | | code description | | MEP-B2E- | | 0.05-level measurement accuracy; 10 times per second measurement and control speed; 5-digit LED display | | Dimensions | AH | 160×80×125 hole size: 152×76 | | CH | 96×48×112 hole size: 92×45 | | Panel Specifications | | 5-digit LED display (-19999~45000) | | input signal | m | mV signal ±20mV, ±50mV, ±90mV | | (Other input signals, please specify when ordering) | I | DC current (4-20) mA, (0-10) mA, (0-20) mA | | V | DC voltage (0-5) V, (1-5) V | | Contact input (option) | K | 1 external switch input for zero setting. | | Alarm (option) | T1~4 | T3, T4 limited to AH (250V AC/3A, resistive load) | | Transmitter (option) (resolution: 1/3000; current output load≦600Ω, voltage output load≧100KΩ) | A1 | Current output (4-20) mA, (0-10) mA, (0-20) mA | | A2 | Voltage output (1-5) V, (0-5) V | | A3 | Voltage output (0-10) V | | External power supply (option) | B1 | 24V±5% below 50mA | | B1G | 24V±5% below 100mA | | B2 | 12V±5% below 50mA | | B2G | 12V±5% below 100mA | | | B3 | Precision power supply, generally 10V±2%, 30ppm, below 100mA | | Communication (option) | S1 | TC ASCII protocol RS232 | | (communication rate: 2400, 4800, 9600, 19200) | S2 | TC ASCII protocol RS485 | | (Communication address: 0~99) | M1 | Modbus-RTU protocol RS232 | | | M2 | Modbus-RTU protocol RS485 | | Power Specifications | V0 | 100-240V AC 50/60Hz | | | V1 | 10-24V AC 50/60 Hz; 10-24V DC (CH only) | |
|