Product Description ADS-DM801/821 Universal Input Signal Isolator is a universal input signal isolator that can support multiple input signals, including thermocouples, thermal resistors, DC current/voltage inputs, and more. These input signals can be selected through parameter settings. The input, output, feeder, and power supply of the isolator are isolated from each other, ensuring the safety and stability of the signal. In the standard configuration, the ADS-DM801/821 Universal Input Signal Isolator provides feeder functionality. Specifically, the standard configuration of the 801 model has one output port, while the standard configuration of the 821 model has two output ports, which are also isolated from each other. The power range of this isolator is 10VDC to 30VDC, and the power consumption is less than 4.8W. This means that it can operate at low power consumption and is suitable for various power supply environments. In summary, ADS-DM801/821 Universal Input Signal Isolator is a powerful and flexible universal input signal isolator that can meet the needs of different application scenarios. Basic Specifications Power supply voltage: 10~30VDC Power consumption: less than 4.8W Environmental temperature: -10~55 ℃ (storage: -25~65 ℃) Environmental humidity: 35~85% RH, no condensation Absolute humidity: MAX. W. C 29.3 g/m3 dry air at 101.3kPa Installation location: indoor, height<2000m Insulation resistance: ≥ 100M Ω (500V DC MEGA reference) Insulation strength: 1000V AC (test conditions: 50/60Hz, 1 minute) Anti interference: IEC61000-4-2 (electrostatic discharge), Class III IEC61000-4-4 (Electrical Fast Transient Pulse Group), Class III IEC61000-4-5 (surge), Class III Input specifications Input: Thermocouple, thermal resistor, DC current/voltage input, input signal set by parameters. Please refer to [Input Signal] for details. Isolation: Input and output, feed, isolator power supply isolation. Conversion cycle: 0.1 seconds (thermocouple input is 0.2 seconds) Basic error: ± 0.2% F • S When the input signal is selected as a B-type thermocouple, accuracy is not guaranteed when it is less than 250 ℃. Cold junction compensation accuracy: it is related to the cold junction compensation mode, the Thermal equilibrium at the terminal and the cold junction compensation coefficient. Feed specifications 24V ± 5% below 50mA Feed and input, output, isolator power supply isolation Output specifications 801 configuration with 1 output 821 is configured with two outputs, with isolation between the two outputs Optoelectronic isolation, resolution: 1/10000, load capacity: 600 Ω The output signal is set by parameters, please refer to [Output] for details Output and input, feed, isolator power supply isolation Code Description content | Code Description | ADS-DM801- | 1 input and 1 output, with an accuracy of 0.2 level; Measurement and control speed 10 times per second | ADS-DM821- | 1 input and 2 outputs, with 0.2 level accuracy; Measurement and control speed 10 times per second | Output 1 (highest resolution: 1/10000; current output load ≤ 600 Ω, voltage output load ≥ 100K Ω) | A1 | Current output (4-20) mA, (0-20) mA, (0-10) mA | A2 | Voltage output (0-5) V, (1-5) V | A3 | Voltage output (0-10) V | Output 2 (maximum resolution: 1/10000; current output load ≤ 600 Ω, voltage output load ≥ 100K Ω) (DM821 only) | A1 | Current output (4-20) mA, (0-20) mA, (0-10) mA | A2 | Voltage output (0-5) V, (1-5) V | A3 | Voltage output (0-10) V | feed | B1 | 24V ± 5% below 50mA | Power specifications | V1 | 10-24V AC 50/60 Hz; 10-30V DC |
|